Gateway 4
LED Indication
Gateway 4 features various LED indicators, which give different informational signals depending on whether the product is booting up or in operational mode.
During boot-up
Power LED:
- Slow flashing green (1Hz) = booting normally
- Slow alternating green/red (1Hz) = factory start (settings cleared)
During operation
Power LED:
- Static green = powered, normal operation
- Fast flashing green (5Hz) = identify**
- Occulting green = remote programming command received
- Static red = fault condition
- Fast alternating green/red (5Hz) = product is not commissioned (return for service)
Net & Link LED:
- Yellow = network link established (but no lighting data)
- Green = Art-Net or sACN detected
- LEDs 1, 2, 3 & 4
- Green = Data activity
- All indicators
- Off = mute command received